摘 要: 介绍了一种凝结水泵采用一拖二变频调速控制的改造方案,分析了变频器的工作原理及系统结构,通过对凝结水泵在不同负荷工况下变频调速控制和工频控制运行情况的比较分析,可知凝结水泵采用高压变频技术具有显著的节能效果,并提高了设备的安全可靠性。
关键词:凝结水泵;变频器;节能
中图分类号:TM344.6 文献标识码:A 文章编号:1007-3175(2013)03-0037-03


Application of High-Voltage Frequency Converter in Condensation Pumps of 600MW Ultra Critical Generation Set 

RAO Yun-tang 
Guangdong Red Bay Generation Co., Ltd, Shanwei 516600, China 
 

Abstract: Introduction was made to a kind of reform plan using one frequency converter to drive two condensate pumps and analysis was made to the working principle and system structure of converter. This paper compared and analyzed variable frequency speed regulation control and working frequency control operation situation of condensate pumps under different load conditions. The result shows that the condensate pump adopting high-voltage variable frequency technology is with obvious energy-saving effect and high safety and reliability.